Power Failure Protection of SSD
SSD Problems caused by power failure:
Generally power
failure would cause 3 main problems to SSD when PC runs.
1. Mapping table might get lost because there
is no enough time to update and store it. Usually SSD manufacturers do not
provide users with tools to recover mapping table. Thus SSD will become
undetectable to host and only method is to return the drive to manufacturer for
repairing. And SSD vendors will reproduce the drives by firmware which will get
all data on SSD lost.
2. SSD mostly deploy DDR or SDRAM as the
cache on board. Once power fails, all data in cache will be lost because both
DDR and SDRAM are non-volatile media. And these data have never been
transferred into NAND flash yet because R/W speed of DDR is far higher than
NAND Flash. However host will consider that data writing has already been
finished. In this way power failure causes data loss.
3. Power failure results in new nominal bad
blocks. ECC of controller checks 256bit data in row and column, and xor each
bit(If result is 0, it means even numbers of 1. If result is 1, it means odd
number of 1). When power failure occurs, there might be errors above 1 bit in 1
block, which cannot be corrected by ECC because it only deals with 1 bit’s
error at 1 time. Then controller will misjudge this block as bad one and will
not use it for new data storing. This is why common SSD tools find increased
bad block numbers after power failure happens.
Renice solution:
Renice deploys
super capacitor or tantalum capacitors on specific SSD models, and detect the
input power from both capacitor’s and SATA power’s input end. Detection circuit
is interfacing with corresponding GPIO so that abnormal signal of power will be
reported to SSD Firmware through GPIO when power fails. When 5v power supply
breaks off, SSD will report to HOST and stop to receive data not reaching SSD.
Renice solution also takes over-current into consideration. Once the input
current is detected to excess limitation, current-limiting circuit (Protection
circuit to prevent damaging over components if instantaneous input current is
too large) will report to SSD controller, as reactions original power supply will
be cut off and capacitors will provide the power required to transfer mapping
table and data in cache into NAND flash.
Validation methods:
Renice’s engineer
team developed our own instrument to produce power blackout in different
operation process, including reading, writing, shutting down, starting up,
rebooting, or even irregular power blackout.
Using this
instrument Renice implements power on-off for 3,000 cycles to verify SSD’s
power failure protection is able to run well in real trial.