Posts

Showing posts from 2019

Renice Rugged 3U VPX SATA SSD Storage Device, 8TB (max up to 10TB)

Image
Specification VPX interface, support 2x SATA (6.0Gbps) Maximum capacity up to 10TB Single-channel SATA maximum sequential Read and Write speed: 530/500MB/s Operating temperature: -40°C~+85°C To learn more, please email may@renice-tech.com or sales@renice-tech.com.

Renice 6U VPX High Performance Computing Blade R6VPX-SE2648-C1I1

Image
Specification CPU: Intel XEON E5 V4 processor Ethernet : 4x Gigabit Ethernet ports, 1x Gigabit Ethernet debugging port 40GbE Ethernet port: 2x 40GbE Ethernet interface RapidIO port: 2x RapidIO ports PCIE interface: 1x PCI-E 3.0 x16 Serial port: 1x RS232, 1x RS422 4x SATA ports 4x USB ports 1x VGA port Slot address port: Mark [0:7] single-port input interface Working voltage: 5V and +12V DC for main power Typical Power Consumption: <150W Cooling Method: Air-cooled (defult), and liquid-cooled Outlook: Standard ASAAC structure Motherboard size: Standard 6U size Operation temperature: -40℃ to +55℃ Storage temperature: -50℃ to +70℃ Humidity: 95% Non-condensing Vibration: 5HZ-2000HZ, 1.5rms (working status) 20-2000HZ, 2Grms (nonworking status) Shock: 20G, 11ms (working status) 30G, 11ms (nonworking status) If interested and need data sheet, please contact Renice at sales@renice-tech.com .

Renice 6U VPX High Performance Computing Blade R6VPX-SE2648-C1I1

Image
Specification CPU: Intel XEON E5 V4 processor Ethernet : 4x Gigabit Ethernet ports, 1x Gigabit Ethernet debugging port 40GbE Ethernet port: 2x 40GbE Ethernet interface RapidIO port: 2x RapidIO ports PCIE interface: 1x PCI-E 3.0 x16 Serial port: 1x RS232, 1x RS422 4x SATA ports 4x USB ports 1x VGA port Slot address port: Mark [0:7] single-port input interface Working voltage: 5V and +12V DC for main power Typical Power Consumption: <150W Cooling Method: Air-cooled (defult), and liquid-cooled Outlook: Standard ASAAC structure Motherboard size: Standard 6U size Operation temperature: -40℃ to +55℃ Storage temperature: -50℃ to +70℃ Humidity: 95% Non-condensing Vibration: 5HZ-2000HZ, 1.5rms (working status) 20-2000HZ, 2Grms (nonworking status) Shock: 20G, 11ms (working status) 30G, 11ms (nonworking status) If interested and need data sheet, please email Renice's distributors or contact us at sales@renice-tech.com .

Renice LRMs module (ASAAC storage control module), 2TB 4TB 8TB 16TB 32TB

Image
Renice LRMs (ASAAC storage control module) is a server storage control module consisting mainly of Intel XEON CPU unit, health management (BMC) unit and related interface controller. The storage control module is linked to the client (server module) through the 10 Gigabit optical fiber, and the transmission protocol adopts the iSCSI protocol; the storage control module implements the mirroring function through the 10 Gigabit interface; the storage control module supports the hard RAID function and outputs the 8-way SATA signal. The module supports physical destruction and logical destruction of the SSD of the server storage module. To learn more, please email Renice at sales@renice-tech.com.

Renice r-Backup® Power Failure Protection of SSD

Image
rBackup (Rapid Backup) refers to a technique of how to flush data stored in DDR into NAND Flash within a very short period. It is developed by Renice to solve the problem that regular power failure protecting mechanism (based on super capacitor or tantalum capacitor) does not work when capacitor ages with power less than initial design as time goes by. Background Mainstream SSD deploy SDRAM or DDR to improve the R/W speed. That follows the issue of data loss or mapping table loss when sudden power failure occurs. To guarantee the data integrity, usually SSD makers design a power failure protecting mechanism based on Super-Capacitor or Tantalum Capacitor, which will work as backup power for SSD in power failure circumstance. This design seems to be perfect to balance the performance and reliability. However there is a potential hazard behind it in real application. Both Super-Capacitor and Tantalum Capacitor keep aging as charge & discharge times increase. Common warranty pe...

Renice ASAAC storage control module

Image
Introduction Renice S6ASC-Z1M1 is a server storage control module consisting mainly of CPU unit, health management (BMC) unit and interrelated interface controller. The storage control module is linked to the client end (server module) through the 10 Gigabit optical fiber, iSCSI transmission protocol. This storage control module implements the mirroring function through the 10 Gigabit interface, supporting the hard RAID function and outputs the 8-channel SATA signal. What's more, the module supports physical destruction and logical destruction of the SSD of the server storage module. The module is mainly used for disaster recovery backup where require high data security, and to improve business continuity and protect customers' data security and business continuity. Highlights Supports server storage modules expansion Supports RAID 0 management to server storage module Supports web management interface Supports multiple server modules to share storage space Suppo...

Renice 32TB 6U Open VPX storage card

Image
VPX P0, P1, P2, P3, P4, P5, P6 interface Size: 6U (233.35mmX160.0mmX25.1mm) Input Voltage: 5V (±5%) or 12V (±5%) Operation Temperature: -40℃ to +85℃ To learn more, please email sales@renice-tech.com

Renice 3U VPX RAID module

Image
Renice released their new 3U VPX RAID module in March 2019, if you want to manage several 3U VPX storage modules at the same time when your system doesn't support RAID, Renice's 3U VPX RAID module is a good solution for you. Specification System configuration: Ubuntu 16.04 (X86 platform), Linux Supports up to 24 SATA bays and supports multiple array management modes 1x channel ethernet interface 4x channels intelligent fan management control interface 20x channels SATA3.0 interface 1x channel PCIe3.0 x8 interface 2x channel USB2.0 interface 4 GPIO interfaces  1x channel universal serial port Supports slot address interface Supports board temperature, voltage, key device status, slot and other information collection, fault reporting functions Typical power consumption: <30W Size: 100x25.4x160mm (L*W*H) Operation temperature: -10 ~ +70℃ Storage temperature: -50~ +100℃ To learn more, please email sales@renice-tech.com.

Renice LS1046-ARM storage server motherboard

Image
Processor: 4 cores ARM COTEX A72, up to 1.8Ghz Memory: DDR4 16GB Storage: 8x SAS or SATA Solid State Drives OS: LINUX PCIe interface: 1 channel X4 PCIE3.0 Internet: 4-channel Gigabit network interface, 2-channel 10 Gigabit network interface, 1x BMC 10M/100M management network port SF8087: 2-channel SF 8087 interface, configurable into 3 X1 PCIe or 1 X4 PCIe interface Power Supply: Provide 1 power input interface, 1 power output interface, 1 power management interface Fan interface: 5 channels (4 lines, PWM, SENCE, 12V, GND) USB interface: 2x USB3.0 host interfaces, 1x USB3.0 device interface Serial port: 1x RS232 universal serial port, 1x RS232 debugging serial port Size: 243.84mm x 243.84mm Operating voltage: the motherboard uses +5V and +12V, 3.3V power supply Typical power consumption: <30W To learn more, please email sales@renice-tech.com.

Renice 6U VPX-S6 High Performance Heterogeneous Acceleration System

Image
Product Introduction VPX acceleration system is a universal service system to satisfy the customer needs for building heterogeneous accelerated computing platforms based on OpenVPX. The system uses 6U VPX standard 19-inch chassis which provides six slots that can be inserted into five service boards and one master board. Service board use Stratix10 FPGA with the latest Intel 14nm integrated the 2573KLE and 9.2TFLOPS single-precision and hard-floating-point capability. It support high-bandwidth and high capacity storage access through FPGA IO extensible feature, the panel and backplane provide a flexible exchanging interconnected interface that support a variety of interface and memory cards expansion. Different combination achieve more powerful application. It achieved the high-density heterogeneous computing acceleration needs at customer side, but also compatible with OpenVPX platform. Accelerated Computer also provides IDE integrated development environment, support Open...

Renice high reliable SSD drive can work in the water

Image

Renice X7 series 2.5" U.2 SFF-8639 NVMe PCIE SSD, 2TB 4TB 8TB I-temp -40 to +85°C

Image
Host Interface: PCIE 2.0 (5Gbps Interface), maximum PCIE 2.0 X4 Size: 2.5 inch Connector: 2.5-inch U.2 (SFF-8639) Capacity: 2TB, 4TB, 8TB Input Voltage: 12V ( ± 8%) Max sequential Read and Write speed: 1200/1000MB/s 4Kb Random Read and Write IOPS: 100,000/90,000 Access time: ≤ 40us MTBF: >1,500,000 Hours @25C UBER: < 1 sector per 1015 bits read, 1 sector = 512 Bytes. TBW: 2TB up to 0.5 PB 4TB up to 1.0 PB 8TB up to 2.0 PB Operating Temp: -40 to +85 ° C To learn more, please email sales@renice-tech.com.

Renice Nand Flash Test System NFA100 Introduction

NFA100 is an extremely powerful and flexible NAND Flash testing platform, clients can test  NAND Flash parameters by using NFA100 system commands and even reprocess these parameters for eventual product development. Clients also can realize their specific testing requirements through API or usage of script commands. Specification: Supports 3D NAND with newest  process, 1x nm and 25nm, 34nm,  56nm Nand. Supports SLC,MLC,TLC,eMLC. Supports 8-bit and 16-bit  Asynchronous Nand. Supports Aynchronous, Toggle Flash. Supports regular NAND from Micron, Toshiba, Samsung, Intel, Sandisk and  Hynix. Supports Nand with TSOP48, BGA63,  BGA100, BGA132, BGA152  packagage. Custom and develop unconventional  and self-defined packaged Nand. Test customer’s self-developed BCH ECC or LDPC  intensity. Test Read Retry. Test NAND Flash at varying voltage. Test of physical destroy over NAND Flash ... To learn more, please refer to NFA100 manual ...

About SSD AES-encryption

Self-encrypting drives use an encryption engine built into the SSD’s controller to encrypt every file stored on the drive. The purpose of AES Encryption is to convert standard input data known as plaintext to an unintelligible output known as cipher text. So if AES encryption on SSD used for data randomization function only, it only provides some data protection in the sense that if the controller is damaged, a 3rd party would not be able to read the data on the flash. In normal usage, however, there would be no data protection as any party that is in possession of the drive can read the data. Methods of using AES on SSD to Secure Data Hardware-based Encryption Self-encrypting drives include dedicated AES encryption engines that do not require software to run on the host. The randomized AES encryption keys are generated at product initialization using the controller’s true random number generator and encrypted in the SSD. This could also be implemented by a Trusted Platform Modu...

Renice release new X7 series MLC 1TB mSATA SATAIII 6.0Gbps SSD, -40°C to +85°C

Image
Form Foctor: mSATA(MO-300) Host interface: SATAIII 6.0Gbps Sequential Read/Write performance: 500/300MB/s Random4k Read/Write performance: 50K/ 50K Power Consumption (Active): 5.1W Operating Temp.: -40°C~+85°C Supports DRAM ECC Supports Encryption mode Supports Hardware Secure erase/ Write protection Supports Military Secure Erase protocol To learn more, please do not hesitate to contact sales@renice-tech.com

Renice X7 2.5" SATA/NVMe 2TB 4TB 8TB Industrial SSD, -40°C to +85°C

Image
Form Factor: 2.5 inch SATA Revision 3.0; compatible with SATA 6Gb/s, 3Gb/s and 1.5Gb/s interface rates Size: 100.45 x 69.85 x 7.0 (or 15.0) mm Capacity: 1TB, 2TB, 4TB, 8TB Sequential 128KB Read: Up to 520 MB/s Sequential 128KB Write: Up to 500 MB/s Random 4KB Read: Up to 70,000 IOPS Random 4KB Write: Up to 70,000 IOPS Read/Write Latency: 65μs/40μs (TYP) Operating Temperature: -40°C to +85°C Non-Operating: -45°C to +90°C Shock (operating and non-operating): 1,000 G/0.5ms Vibration 6 Operating: 16.3 GRMS (10-2,000 Hz) MTBF: 1.5 million hours 3 Power consumption Active: Up to 6.09W (8TB, Avg.) Idle: Up to 2.73W (8TB, Avg.) Product Ecological Compliance: RoHS To learn more, please email sales@renice-tech.com

The advantages of X9 R-SATA SSD

Image
Renice X9 R-SATA Technical Highlight 1. Secure Erase, support Physical Destroy and Logical Destroy 1.1. Physical destroy Implemented by HW button, with time-sharing shunt design to guarantee each NAND Flash been destroyed. The disk is scraped after destroy and data cannot be recovered by any means. 1.2. Logical destroy Support SW and HW methods. 1.2.1 After data destruction, the disk cannot be recognized by HOST, and data cannot be recovered by any means; 1.2.2 After destruction, all data in disk become FF, cannot be recovered. The disk is enabling to be used after initialization. 2. r-Backup technical patent, to keep the integrity of data information under abnormal power-off even when capacitor aging after years usage; 3. Exclusive Non-Balance wear-leveling technology, to increase the lifespan of the disk. 4. Support write-protect function 5. Support the only corresponds: the disk and the host computer. The destruction will be started automatically when the d...