Posts

Renice 6U VPX High Performance Computing Blade R6VPX-SE2648-C1I1

Image
Specification CPU: Intel XEON E5 V4 processor Ethernet : 4x Gigabit Ethernet ports, 1x Gigabit Ethernet debugging port 40GbE Ethernet port: 2x 40GbE Ethernet interface RapidIO port: 2x RapidIO ports PCIE interface: 1x PCI-E 3.0 x16 Serial port: 1x RS232, 1x RS422 4x SATA ports 4x USB ports 1x VGA port Slot address port: Mark [0:7] single-port input interface Working voltage: 5V and +12V DC for main power Typical Power Consumption: <150W Cooling Method: Air-cooled (defult), and liquid-cooled Outlook: Standard ASAAC structure Motherboard size: Standard 6U size Operation temperature: -40℃ to +55℃ Storage temperature: -50℃ to +70℃ Humidity: 95% Non-condensing Vibration: 5HZ-2000HZ, 1.5rms (working status) 20-2000HZ, 2Grms (nonworking status) Shock: 20G, 11ms (working status) 30G, 11ms (nonworking status) If interested and need data sheet, please contact Renice at sales@renice-tech.com .

Renice 6U VPX High Performance Computing Blade R6VPX-SE2648-C1I1

Image
Specification CPU: Intel XEON E5 V4 processor Ethernet : 4x Gigabit Ethernet ports, 1x Gigabit Ethernet debugging port 40GbE Ethernet port: 2x 40GbE Ethernet interface RapidIO port: 2x RapidIO ports PCIE interface: 1x PCI-E 3.0 x16 Serial port: 1x RS232, 1x RS422 4x SATA ports 4x USB ports 1x VGA port Slot address port: Mark [0:7] single-port input interface Working voltage: 5V and +12V DC for main power Typical Power Consumption: <150W Cooling Method: Air-cooled (defult), and liquid-cooled Outlook: Standard ASAAC structure Motherboard size: Standard 6U size Operation temperature: -40℃ to +55℃ Storage temperature: -50℃ to +70℃ Humidity: 95% Non-condensing Vibration: 5HZ-2000HZ, 1.5rms (working status) 20-2000HZ, 2Grms (nonworking status) Shock: 20G, 11ms (working status) 30G, 11ms (nonworking status) If interested and need data sheet, please email Renice's distributors or contact us at sales@renice-tech.com .

Renice LRMs module (ASAAC storage control module), 2TB 4TB 8TB 16TB 32TB

Image
Renice LRMs (ASAAC storage control module) is a server storage control module consisting mainly of Intel XEON CPU unit, health management (BMC) unit and related interface controller. The storage control module is linked to the client (server module) through the 10 Gigabit optical fiber, and the transmission protocol adopts the iSCSI protocol; the storage control module implements the mirroring function through the 10 Gigabit interface; the storage control module supports the hard RAID function and outputs the 8-way SATA signal. The module supports physical destruction and logical destruction of the SSD of the server storage module. To learn more, please email Renice at sales@renice-tech.com.

Renice r-Backup® Power Failure Protection of SSD

Image
rBackup (Rapid Backup) refers to a technique of how to flush data stored in DDR into NAND Flash within a very short period. It is developed by Renice to solve the problem that regular power failure protecting mechanism (based on super capacitor or tantalum capacitor) does not work when capacitor ages with power less than initial design as time goes by. Background Mainstream SSD deploy SDRAM or DDR to improve the R/W speed. That follows the issue of data loss or mapping table loss when sudden power failure occurs. To guarantee the data integrity, usually SSD makers design a power failure protecting mechanism based on Super-Capacitor or Tantalum Capacitor, which will work as backup power for SSD in power failure circumstance. This design seems to be perfect to balance the performance and reliability. However there is a potential hazard behind it in real application. Both Super-Capacitor and Tantalum Capacitor keep aging as charge & discharge times increase. Common warranty pe...

Renice ASAAC storage control module

Image
Introduction Renice S6ASC-Z1M1 is a server storage control module consisting mainly of CPU unit, health management (BMC) unit and interrelated interface controller. The storage control module is linked to the client end (server module) through the 10 Gigabit optical fiber, iSCSI transmission protocol. This storage control module implements the mirroring function through the 10 Gigabit interface, supporting the hard RAID function and outputs the 8-channel SATA signal. What's more, the module supports physical destruction and logical destruction of the SSD of the server storage module. The module is mainly used for disaster recovery backup where require high data security, and to improve business continuity and protect customers' data security and business continuity. Highlights Supports server storage modules expansion Supports RAID 0 management to server storage module Supports web management interface Supports multiple server modules to share storage space Suppo...

Renice 32TB 6U Open VPX storage card

Image
VPX P0, P1, P2, P3, P4, P5, P6 interface Size: 6U (233.35mmX160.0mmX25.1mm) Input Voltage: 5V (±5%) or 12V (±5%) Operation Temperature: -40℃ to +85℃ To learn more, please email sales@renice-tech.com